Manhole Cover Load Classes: EN 124 Guide (A15 to F900)

Which load class does a manhole cover or grating need? The EN 124 classes explained, with the Indian IS 1726 grades for comparison.

Every manhole cover, access cover and gully grating is made for a certain load. In the UK, Europe and many export markets the load is given by a class of the standard EN 124 (in the UK: BS EN 124). The class is a letter and a number: the number is the test load in kilonewtons (kN) the cover and frame must carry without breaking. The letter stands for the place where the product may be installed.

Choosing the class is the most important decision when you specify a cover: a cover that is too light for the traffic can crack or rock; one that is far heavier than needed costs more and is harder to lift.

The six EN 124 load classes

ClassTest loadGroupWhere it is used
A1515 kN (about 1.5 tonnes)1Areas used only by pedestrians and cyclists: gardens, patios, cycle paths
B125125 kN (about 12.5 tonnes)2Footways, pedestrian areas and comparable areas, private car parks and parking decks
C250250 kN (about 25 tonnes)3Kerbside channels of roads: up to 0.5 m into the carriageway and 0.2 m into the footway, measured from the kerb
D400400 kN (about 40 tonnes)4Carriageways of roads (including pedestrian streets), hard shoulders and parking areas for all road vehicles
E600600 kN (about 60 tonnes)5Areas with high wheel loads: docks, loading yards, forklift traffic
F900900 kN (about 90 tonnes)6Areas with particularly high wheel loads, such as airport pavements

How to choose the right class

  • Start from the place of installation, not from the vehicle: the standard gives the minimum class for each place (the groups in the table).
  • Think about what may happen later. A footway cover that cars or delivery vans may drive over needs at least C250; if lorries can reach it, choose D400.
  • Kerbside gratings sit where wheels often run: C250 is the minimum, D400 where heavy traffic is frequent.
  • Roads and car parks for all vehicles need D400. Busy or high-speed roads also need covers that do not rock and do not make noise, such as double triangular or cushioned designs.
  • Follow the project specification. When the specification and this guide differ, the specification applies. When in doubt, choose the higher class.

EN 124 and the Indian standard IS 1726

For cast iron manhole covers in India, IS 1726 uses four grades named after their test load in tonnes. They are not the same as the EN 124 classes, so a cover should always be ordered in the system the project specification uses.

IS 1726 gradeTest loadClosest EN 124 class by test load
LD-2.5 (light duty)2.5 tonnes (about 25 kN)between A15 and B125
MD-10 (medium duty)10 tonnes (about 100 kN)below B125
HD-20 (heavy duty)20 tonnes (about 200 kN)between B125 and C250
EHD-35 (extra heavy duty)35 tonnes (about 350 kN)between C250 and D400

Ductile iron or grey cast iron?

Both are cast iron. In ductile iron (spheroidal graphite or S.G. iron) the graphite forms round nodules, which makes the metal much stronger and less brittle. A ductile iron cover is therefore lighter than a grey iron cover of the same class and resists impact better, which is why most D400 covers for roads are ductile iron. Grey cast iron, with flake graphite, is heavier for the same strength but economical, and is widely used for lighter-duty covers, gratings and frames.

JPK Metallics covers and gratings by load class

  • A15: lightweight circular cover for pedestrian areas, gardens and cycle paths (Solid Top, Arcline Lite).
  • B125: solid top, recessed, double triangular covers and gratings for footways and car parks (Solid Top, Recessed Covers, Gratings).
  • C250: covers and gratings for kerbside areas and city traffic (Solid Top, Gratings).
  • D400: heavy-duty covers for roads and highways, including double triangular and multi-leaf covers (Double Triangular, Solid Top).

Selected D400 covers are made to BS EN 124 and some ranges carry the BSI Kitemark; each product page shows which.

This guide summarises EN 124 and IS 1726 for choosing a product. For design and approval, always use the current edition of the standard and your project specification.

Not sure which class you need? Send us the place of installation, the size and the quantity, and we will recommend a cover.

Ask our team